Low Noise VPSA Oxygen Generator with Long Maintenance Cycle and Modular Design for Industrial Use

Low Noise VPSA Oxygen Generator with Long Maintenance Cycle and Modular Design for Industrial Use

Low Noise VPSA Oxygen Generator with Long Maintenance Cycle and Modular Design for Industrial Use
Low Noise VPSA Oxygen Generator with Long Maintenance Cycle and Modular Design for Industrial Use Low Noise VPSA Oxygen Generator with Long Maintenance Cycle and Modular Design for Industrial Use Low Noise VPSA Oxygen Generator with Long Maintenance Cycle and Modular Design for Industrial Use Low Noise VPSA Oxygen Generator with Long Maintenance Cycle and Modular Design for Industrial Use

বড় ইমেজ :  Low Noise VPSA Oxygen Generator with Long Maintenance Cycle and Modular Design for Industrial Use

পণ্যের বিবরণ:
উৎপত্তি স্থল: চীন
পরিচিতিমুলক নাম: GNEE
সাক্ষ্যদান: SGS
প্রদান:
ন্যূনতম চাহিদার পরিমাণ: ≥1sets
মূল্য: According to the product
ডেলিভারি সময়: ট্রানজিট সময়: EST। 17-24 দিন
পরিশোধের শর্ত: এল/সি, ডি/এ, ডি/পি, টি/টি, মানিগ্রাম, ওয়েস্টার্ন ইউনিয়ন

Low Noise VPSA Oxygen Generator with Long Maintenance Cycle and Modular Design for Industrial Use

বিবরণ
ক্ষমতা: 100,000 Nm3/ঘণ্টা পর্যন্ত উত্পাদন হার: 300-10000nm3/ঘন্টা
নির্মাণ সামগ্রী: স্টেইনলেস স্টীল শব্দ স্তর: ≤75 ডিবি (ক)
রক্ষণাবেক্ষণ চক্র: ≥8000 ঘন্টা অভ্যন্তরীণ পাত্র উপাদান: 304 স্টেইনলেস স্টীল
তাপমাত্রা: পরিবেষ্টিত স্বীকৃতি: নতুন
অপারেশন মোড: ক্রমাগত যন্ত্রপাতি পরীক্ষার রিপোর্ট: প্রদান করা হয়েছে
বিশেষভাবে তুলে ধরা:

Low Noise VPSA Oxygen Generator

,

Long Maintenance Cycle VPSA Oxygen Plant

,

Modular Design Oxygen Production Equipment

High Quality VPSA Oxygen Plant
With molecular sieves as the core separation medium, our VPSA Oxygen Generator efficiently separates oxygen and nitrogen components in the air through the alternation of low-pressure adsorption and vacuum desorption, producing oxygen that meets both industrial and medical standards. Key advantages include:
  • Low power consumption (0.32-0.38kWh/Nm³)
  • Fast start-up capability
  • Simple maintenance requirements
  • Modular design for flexible production capacity
Product Specifications
Model No. Flow Rate (Nm³/h) Purity
VPSA-5 5 93±2%
VPSA-10 10 93±2%
VPSA-20 20 93±2%
VPSA-30 30 93±2%
VPSA-40 40 93±2%
VPSA-50 50 93±2%
VPSA-60 60 93±2%
VPSA-70 70 93±2%
VPSA-80 80 93±2%
VPSA-100 100 93±2%
VPSA-120 120 93±2%
VPSA-150 150 93±2%
VPSA-180 180 93±2%
VPSA-200 200 93±2%
Low Noise VPSA Oxygen Generator with Long Maintenance Cycle and Modular Design for Industrial Use 0 Low Noise VPSA Oxygen Generator with Long Maintenance Cycle and Modular Design for Industrial Use 1 Low Noise VPSA Oxygen Generator with Long Maintenance Cycle and Modular Design for Industrial Use 2
Pre-Installation Site Requirements

Before installing a VPSA Oxygen Generator, ensure the site meets these critical requirements:

  • Structural Requirements: Flat, solid surface with floor bearing capacity of 5kN/m² (small units) to 15kN/m² (large systems). Foundation must use C30 concrete with steel plates (≥12mm thickness) for equipment fixation.
  • Environmental Conditions: Well-ventilated area (≥3 air changes/hour) with relative humidity ≤85%. Avoid dust sources or install appropriate filtration.
  • Space Requirements: Minimum 1.5m clearance from walls/obstacles for maintenance access.
Installation Process

The installation involves three key stages:

  • Equipment Positioning: Level adjustment (≤0.5mm/m deviation) and secure anchoring of blower/vacuum pump.
  • Pipeline Connection: Use corrosion-resistant stainless steel pipes (304/316L) with 1‰-3‰ slope. PTFE gaskets for airtight seals followed by pressure testing (1.2× working pressure for 30 minutes).
  • Electrical Installation: 380V/50Hz three-phase supply with dedicated circuit (≤30mA leakage protection). Grounding resistance ≤4Ω. PLC system integration via Modbus protocol if required.
Maintenance Guidelines

Daily: Monitor pressure (0.1-0.3MPa) and flow (±5% of rated value). Clean air pre-filter.

Weekly: Inspect seals for leaks (soapy water test). Check blower/vacuum pump oil levels.

Monthly: Calibrate oxygen purity sensor. Test pressure relief valve functionality.

Troubleshooting: For purity below 90%, check filter and molecular sieve condition. Excessive vibration may indicate loose bolts or bearing wear. Molecular sieve replacement typically required every 5-8 years depending on usage intensity.

We also manufacture PSA Oxygen Generators, storage tanks, and heat exchangers. For inquiries about VPSA Oxygen Systems or other products, please contact us at info@gneeheatex.com.